x
Our website uses cookies. By using the website you agree ot its use. More information can be found in our privacy policy.

An Assessment of the LS-DYNA Hourglass Formulations via the 3D Patch Test

The six hourglass formulations available in LS-DYNA for 8 node hexahedral elements are evaluated using the so called ‘3D Patch Test.’. It is demonstrated that three of the six hourglass formulations fail this patch test, including the popular default LS-DYNA viscous form of hourglass control. A detailed description of the 3D Patch Test is provided to allow readers to perform the simple test as part of their code verification.